Insulin Lispro is a prescription medicine (Insulin Analog). The sections below reproduce one FDA label for it, named under "Label". Products in other forms, strengths or from other makers have their own labels, which can differ.
- Type
- Prescription only (Rx)
- Brand names
- Humalog KwikPen, Admelog, Humalog, Lyumjev, Humalog Junior KwikPen, Humalog Mix50/50 KwikPen, Humalog Mix75/25, Humalog Mix75/25 KwikPen, Humalog Tempo Pen, LYUMJEV Junior KwikPen, LYUMJEV KwikPen, LYUMJEV Tempo Pen
- Drug class
- Insulin Analog
- Taken
- Subcutaneous
- Label
- Eli Lilly and Company, revised July 27, 2026 · full label on DailyMed
- Biosimilars
- 1 approved · details
What it is used for
HUMALOG Mix50/50 is indicated to improve glycemic control in adults with diabetes mellitus. HUMALOG ® Mix50/50™ is a mixture of insulin lispro protamine, an intermediate-acting human insulin analog, and insulin lispro, a rapid-acting human insulin analog, indicated to improve glycemic control in adults with diabetes mellitus. ( 1 ) Limitations of Use: The proportions of rapid-acting and intermediate-acting insulins are fixed and do not allow for basal versus prandial dose adjustments. ( 1 ) Limitations of Use The proportions of rapid-acting and intermediate-acting insulins in HUMALOG Mix50/50 are fixed and do not allow for basal versus prandial dose adjustments.
Forms and strengths
Injectable suspension: 100 units/mL (U-100) of HUMALOG Mix50/50, 50% insulin lispro protamine and 50% insulin lispro, is a white and cloudy suspension available as: 3 mL single-patient-use KwikPen prefilled pen Injectable suspension: 100 units/mL (U-100) of HUMALOG Mix50/50, 50% insulin lispro protamine and 50% insulin lispro available as: ( 3 ) 3 mL single-patient-use KwikPen ® prefilled pen
Who should not take it (contraindications)
HUMALOG Mix50/50 is contraindicated: during episodes of hypoglycemia [see Warnings and Precautions ( 5.3 )] in patients who have had hypersensitivity reactions to HUMALOG Mix50/50 or to any of its excipients [see Warnings and Precautions ( 5.5 )] Do not use during episodes of hypoglycemia. ( 4 ) Do not use in patients with hypersensitivity to HUMALOG Mix50/50 or any of its excipients. ( 4 )
Warnings and precautions
Never share a HUMALOG Mix50/50 KwikPen between patients, even if the needle is changed. ( 5.1 ) Hyperglycemia or Hypoglycemia with Changes in Insulin Regimen: Make changes to a patient's insulin regimen (e.g., insulin strength, manufacturer, type, injection site or method of administration) under close medical supervision with increased frequency of blood glucose monitoring. ( 5.2 ) Hypoglycemia: May be life-threatening. Increase frequency of blood glucose monitoring with changes to insulin dosage, co-administered glucose lowering medications, meal pattern, physical activity; in patients with renal or hepatic impairment; and in patients with hypoglycemia unawareness. ( 5.3 ) Hypoglycemia Due to Medication Errors: Accidental mix-ups between insulin products can occur. Instruct patients to check insulin labels before injection. ( 5.4 ) Hypersensitivity Reactions: Severe, life-threatening, generalized allergy, including anaphylaxis, can occur. Discontinue HUMALOG Mix50/50, monitor and treat if indicated. ( 5.5 ) Hypokalemia: May be life-threatening. Monitor potassium levels in patients at risk of hypokalemia and treat if indicated. ( 5.6 ) Fluid Retention and Heart Failure with Concomitant Use of Thiazolidinediones (TZDs) : Observe for signs and symptoms of heart failure; consider dosage reductions or discontinuation if heart failure occurs. ( 5.7 )
5.1 Never Share a HUMALOG Mix50/50 KwikPen Between Patients HUMALOG Mix50/50 KwikPens must never be shared between patients, even if the needle is changed. Sharing poses a risk for transmission of blood-borne pathogens.
5.2 Hyperglycemia or Hypoglycemia with Changes in Insulin Regimen Changes in an insulin regimen (e.g., insulin strength, manufacturer, type, injection site or method of administration) may affect glycemic control and predispose to hypoglycemia [see Warnings and Precautions ( 5.3 )] or hyperglycemia. Repeated insulin injections into areas of lipodystrophy or localized cutaneous amyloidosis have been reported to result in hyperglycemia; and a sudden change in the injection site (to an unaffected area) has been reported to result in hypoglycemia [see Adverse Reactions ( 6 )] . Make any changes to a patient's insulin regimen under close medical supervision with increased frequency of blood glucose monitoring. Advise patients who have repeatedly injected into areas of lipodystrophy or localized cutaneous amyloidosis to change the injection site to unaffected areas and closely monitor for hypoglycemia. For patients with type 2 diabetes, dosage adjustments of concomitant anti-diabetic products may be needed.
5.3 Hypoglycemia Hypoglycemia is the most common adverse reaction associated with all insulins, including HUMALOG Mix50/50. Severe hypoglycemia can cause seizures, may lead to unconsciousness, may be life-threatening, or cause death. Hypoglycemia can impair concentration ability and reaction time, this may place an individual and others at risk in situations where these abilities are important (e.g., driving or operating other machinery). Hypoglycemia can happen suddenly, and symptoms may differ in each individual and change over time in the same individual. Symptomatic awareness of hypoglycemia may be less pronounced in patients with longstanding diabetes, in patients with diabetic nerve disease, in patients using medications that block the sympathetic nervous system (e.g., beta-blockers) [see Drug Interactions ( 7 )], or in patients who experience recurrent hypoglycemia. Risk Factors for Hypoglycemia The risk of hypoglycemia after an injection is related to the duration of action of the insulin and in general, is highest when the glucose lowering effect of the insulin is maximal. As with all insulins, the glucose lowering effect time course of HUMALOG Mix50/50 may vary in different individuals or at different times in the same individual and depends on many conditions, including the area of injection as well as the injection site blood supply and temperature [see Clinical Pharmacology ( 12.2 )] . Other factors which may increase the risk of hypoglycemia include changes in meal pattern (e.g., macronutrient content or timing of meals), changes in level of physical activity, or changes to co-administered medication [see Drug Interactions ( 7 )] . Patients with renal or hepatic impairment may be at higher risk of hypoglycemia [see Use in Specific Populations ( 8.6 , 8.7 )] . Risk Mitigation Strategies for Hypoglycemia Patients and caregivers must be educated to recognize and manage hypoglycemia. Self-monitoring of blood glucose plays an essential role in the prevention and management of hypoglycemia. In patients at higher risk for hypoglycemia and patients who have reduced symptomatic awareness of hypoglycemia, increased frequency of blood glucose monitoring is recommended.
5.4 Hypoglycemia Due to Medication Errors Accidental mix-ups between insulin products have been reported. To avoid medication errors between HUMALOG Mix50/50 and other insulins, instruct patients to always check the insulin label before each injection.
5.5 Hypersensitivity Reactions Severe, life-threatening, generalized allergy, including anaphylaxis, can occur with insulins, including HUMALOG Mix50/50. If hypersensitivity reactions occur, discontinue HUMALOG Mix50/50; treat per standard of care and monitor until symptoms and signs resolve. HUMALOG Mix50/50 is contraindicated in patients who have had hypersensitivity reactions to HUMALOG Mix50/50 or any of its excipients [see Contraindications ( 4 )] .
5.6 Hypokalemia All insulins, including HUMALOG Mix50/50, cause a shift in potassium from the extracellular to intracellular space, possibly leading to hypokalemia. Untreated hypokalemia may cause respiratory paralysis, ventricular arrhythmia, and death. Monitor potassium levels in patients at risk for hypokalemia if indicated (e.g., patients using potassium-lowering medications, patients taking medications sensitive to serum potassium concentrations).
5.7 Fluid Retention and Heart Failure with Concomitant Use of PPAR-gamma Agonists Thiazolidinediones (TZDs), which are peroxisome proliferator-activated receptor (PPAR)-gamma agonists, can cause dose-related fluid retention, particularly when used in combination with insulin. Fluid retention may lead to or exacerbate heart failure. Patients treated with insulin, including HUMALOG Mix50/50, and a PPAR-gamma agonist should be observed for signs and symptoms of heart failure. If heart failure develops, it should be managed according to current standards of care, and discontinuation or dose reduction of the PPAR-gamma agonist must be considered.
Side effects (adverse reactions)
The following adverse reactions are discussed elsewhere in the labeling: Hypoglycemia [see Warnings and Precautions ( 5.3 )] Hypoglycemia Due to Medication Errors [see Warnings and Precautions ( 5.4 )] Hypersensitivity Reactions [see Warnings and Precautions ( 5.5 )] Hypokalemia [see Warnings and Precautions ( 5.6 )] Adverse reactions observed with HUMALOG Mix50/50 include hypoglycemia, allergic reactions, injection site reactions, lipodystrophy, weight gain, edema, pruritus, and rash. ( 6 ) To report SUSPECTED ADVERSE REACTIONS, contact Eli Lilly and Company at 1-800-LillyRx (1-800-545-5979) or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch. Adverse Reactions from Clinical Studies or Postmarketing Reports The following adverse reactions have been identified during post-marketing use of HUMALOG Mix50/50. Because some of these reactions are reported voluntarily from a population of uncertain size, it is not always possible to reliably estimate their frequency or establish a causal relationship to drug exposure. Adverse reactions associated with insulin initiation and glucose control intensification Intensification or rapid improvement in glucose control has been associated with a transitory, reversible ophthalmologic refraction disorder, worsening of diabetic retinopathy, and acute painful peripheral neuropathy. Over the long-term, improved glycemic control decreases the risk of diabetic retinopathy and neuropathy. Hypersensitivity reactions Severe, life-threatening, generalized allergy, including anaphylaxis. Hypoglycemia Hypoglycemia is the most commonly observed adverse reaction in HUMALOG Mix50/50. Hypokalemia HUMALOG Mix50/50 can cause a shift in potassium from the extracellular to intracellular space, possibly leading to hypokalemia. Injection site reactions HUMALOG Mix50/50 can cause local injection site reactions including redness, swelling, or itching at the site of injection. These reactions usually resolve in a few days to a few weeks, but in some occasions, may require discontinuation. Localized reactions and generalized myalgias have been reported with the use of meta-cresol, which is an excipient in HUMALOG Mix50/50. Lipodystrophy Administration of insulin subcutaneously, including HUMALOG Mix50/50, has resulted in lipoatrophy (depression in the skin) or lipohypertrophy (enlargement or thickening of tissue) [see Dosage and Administration ( 2.1 )] in some patients. Localized cutaneous amyloidosis Localized cutaneous amyloidosis at the injection site has occurred. Hyperglycemia has been reported with repeated insulin injections into areas of localized cutaneous amyloidosis; hypoglycemia has been reported with a sudden change to an unaffected injection site. Medication Errors Medication errors in which other insulins have been accidentally substituted for HUMALOG Mix50/50 have been identified during postapproval use. Peripheral Edema Insulins, including HUMALOG Mix50/50, may cause sodium retention and edema, particularly if previously poor metabolic control is improved by intensified insulin therapy. Weight gain Weight gain can occur with insulins, including HUMALOG Mix50/50, and has been attributed to the anabolic effects of insulin and the decrease in glycosuria. Immunogenicity As with all therapeutic proteins, insulin administration may cause anti-insulin antibodies to form. The incidence of antibody formation with HUMALOG Mix50/50 is unknown.
Drug interactions
Table 1 describes the clinically significant drug interactions with HUMALOG Mix50/50. Table 1: Clinically Significant Drug Interactions with HUMALOG Mix50/50 Drugs that May Increase the Risk of Hypoglycemia Drugs: Antidiabetic agents, ACE inhibitors, angiotensin II receptor blocking agents, disopyramide, fibrates, fluoxetine, monoamine oxidase inhibitors, pentoxifylline, pramlintide, salicylates, somatostatin analog (e.g., octreotide), and sulfonamide antibiotics. Intervention: Dose adjustment and increased frequency of glucose monitoring may be required when HUMALOG Mix50/50 is co-administered with these drugs. Drugs that May Decrease the Blood Glucose Lowering Effect of HUMALOG Mix50/50 Drugs: Atypical antipsychotics (e.g., olanzapine and clozapine), corticosteroids, danazol, diuretics, estrogens, glucagon, isoniazid, niacin, oral contraceptives, phenothiazines, progestogens (e.g., in oral contraceptives), protease inhibitors, somatropin, sympathomimetic agents (e.g., albuterol, epinephrine, terbutaline), and thyroid hormones. Intervention: Dose adjustment and increased frequency of glucose monitoring may be required when HUMALOG Mix50/50 is co-administered with these drugs. Drugs that May Increase or Decrease the Blood Glucose Lowering Effect of HUMALOG Mix50/50 Drugs: Alcohol, beta-blockers, clonidine, and lithium salts. Pentamidine may cause hypoglycemia, which may sometimes be followed by hyperglycemia. Intervention: Dose adjustment and increased frequency of glucose monitoring may be required when HUMALOG Mix50/50 is co-administered with these drugs. Drugs that May Blunt Signs and Symptoms of Hypoglycemia Drugs: Beta-blockers, clonidine, guanethidine, and reserpine. Intervention: Increased frequency of glucose monitoring may be required when HUMALOG Mix50/50 is co-administered with these drugs. Drugs that may increase the risk of hypoglycemia: antidiabetic agents, ACE inhibitors, angiotensin II receptor blocking agents, disopyramide, fibrates, fluoxetine, monoamine oxidase inhibitors, pentoxifylline, pramlintide, salicylates, somatostatin analog (e.g., octreotide), and sulfonamide antibiotics. ( 7 ) Drugs that may decrease the blood glucose lowering effect: atypical antipsychotics, corticosteroids, danazol, diuretics, estrogens, glucagon, isoniazid, niacin, oral contraceptives, phenothiazines, progestogens (e.g., in oral contraceptives), protease inhibitors, somatropin, sympathomimetic agents (e.g., albuterol, epinephrine, terbutaline), and thyroid hormones. ( 7 ) Drugs that may increase or decrease the blood glucose lowering effect: alcohol, beta-blockers, clonidine, lithium salts, and pentamidine. ( 7 ) Drugs that may blunt the signs and symptoms of hypoglycemia: beta-blockers, clonidine, guanethidine, and reserpine. ( 7 )
Pregnancy, breastfeeding, children and older adults
8.1 Pregnancy Risk Summary Published studies with insulin lispro used during pregnancy have not reported an association between insulin lispro and the induction of major birth defects, miscarriage, or adverse maternal or fetal outcomes (see Data). There are risks to the mother and fetus associated with poorly controlled diabetes in pregnancy (see Clinical Considerations). Pregnant rats and rabbits were exposed to insulin lispro in animal reproduction studies during organogenesis. No adverse effects on embryo/fetal viability or morphology were observed in offspring of rats exposed to insulin lispro at a dose approximately 3 times the human subcutaneous dose of 1 unit insulin lispro/kg/day. No adverse effects on embryo/fetal development were observed in offspring of rabbits exposed to insulin lispro at doses up to approximately 0.2 times the human subcutaneous dose of 1 unit/kg/day (see Data). The estimated background risk of major birth defects is 6-10% in women with pre-gestational diabetes with a HbA1c >7 and has been reported to be as high as 20-25% in women with a HbA1c >10. The estimated background risk of miscarriage for the indicated population is unknown. In the U.S. general population, the estimated background risk of major birth defects and miscarriage in clinically recognized pregnancies is 2-4% and 15-20%, respectively. Clinical Considerations Disease-associated maternal and/or embryo/fetal risk Poorly controlled diabetes in pregnancy increases the maternal risk for diabetic ketoacidosis, pre-eclampsia, spontaneous abortions, preterm delivery, and delivery complications. Poorly controlled diabetes increases the fetal risk for major birth defects, still birth, and macrosomia related morbidity. Data Human Data Published data from retrospective studies and meta-analyses do not report an association with insulin lispro and major birth defects, miscarriage, or adverse maternal or fetal outcomes when insulin lispro is used during pregnancy. However, these studies cannot definitely establish or exclude the absence of any risk because of methodological limitations including small sample size, selection bias, confounding by unmeasured factors, and some lacking comparator groups. Animal Data Animal reproduction studies have not been performed with HUMALOG Mix50/50. However, subcutaneous reproduction and teratology studies have been conducted with insulin lispro (a component of HUMALOG Mix50/50). In a combined fertility and embryo-fetal development study, female rats were given subcutaneous insulin lispro injections of 1, 5, and 20 units/kg/day (0.2, 0.8, and 3 times the human subcutaneous dose of 1 unit insulin lispro/kg/day, based on units/body surface area, respectively) from 2 weeks prior to cohabitation through Gestation Day 19. There were no adverse effects on female fertility, implantation, or fetal viability and morphology. However, fetal growth retardation was produced at the 20 units/kg/day-dose as indicated by decreased fetal weight and an increased incidence of fetal runts/litter. In an embryo-fetal development study in pregnant rabbits, insulin lispro doses of 0.1, 0.25, and 0.75 unit/kg/day (0.03, 0.08, and 0.2 times the human subcutaneous dose of 1 unit insulin lispro/kg/day, based on units/body surface area, respectively) were injected subcutaneously on Gestation days 7 through 19. There were no adverse effects on fetal viability, weight, and morphology at any dose.
8.2 Lactation Risk Summary Available data from published literature suggests that exogenous human insulin products, including insulin lispro, are transferred into human milk. There are no adverse reactions reported in breastfed infants in the literature. There are no data on the effects of exogenous human insulin products, including insulin lispro, on milk production. The developmental and health benefits of breastfeeding should be considered along with the mother's clinical need for insulin, any potential adverse effects on the breastfed child from HUMALOG Mix50/50 or from the underlying maternal condition.
8.4 Pediatric Use Safety and effectiveness of HUMALOG Mix50/50 in pediatric patients have not been established.
8.5 Geriatric Use Clinical studies of Humalog Mix50/50 did not include sufficient numbers of patients aged 65 and over to determine whether they respond differently than younger patients. In elderly patients with diabetes, the initial dosing, dose increments, and maintenance dosage should be conservative to reduce the risk of hypoglycemia [see Warnings and Precautions ( 5.3 )].
8.6 Renal Impairment The effect of renal impairment on the pharmacokinetics of HUMALOG Mix50/50 has not been studied. Patients with renal impairment may be at increased risk of hypoglycemia and may require more frequent HUMALOG Mix50/50 dose adjustment and more frequent glucose monitoring [see Warnings and Precautions ( 5.3 )] .
8.7 Hepatic Impairment The effect of hepatic impairment on the pharmacokinetics of HUMALOG Mix50/50 has not been studied. Patients with hepatic impairment may be at increased risk of hypoglycemia and may require more frequent HUMALOG Mix50/50 dose adjustment and more frequent glucose monitoring [see Warnings and Precautions ( 5.3 )] .
How it works
The primary activity of insulin including HUMALOG Mix50/50 is the regulation of glucose metabolism. Insulins lower blood glucose by stimulating peripheral glucose uptake by skeletal muscle and fat, and by inhibiting hepatic glucose production. Insulins inhibit lipolysis and proteolysis, and enhance protein synthesis.
Are there biosimilars to Insulin Lispro?
Yes. The FDA has approved 1 biosimilars; 1 of those approvals are active (not discontinued). As with generics, approval does not guarantee a product is stocked or covered.
- Lyumjev Eli Lilly And Co, approved 2020
Biologics have biosimilars rather than generics: highly similar versions with no clinically meaningful differences. Only biosimilars the FDA designates as interchangeable can be swapped at the pharmacy without asking the prescriber, where state law allows; the FDA Purple Book lists which ones are.
Brand-name versions
- Humalog Lilly, approved 1996
- Humalog Kwikpen Eli Lilly And Co, approved 2015
- Admelog Sanofi-aventis Us, approved 2017
Source: Drugs@FDA (via openFDA), checked October 29, 2026. Marketing status is what companies report to the FDA; whether a pharmacy stocks a product, and what your insurance covers, can differ.
Dosage:
we do not reproduce dosing instructions. The right dose depends on the person and the condition and is set by the prescriber or pharmacist. Dosage section of the full label.
Insulin lispro in the news
We have not covered this medicine yet. Latest news
Products being discontinued
| Product | Availability | Expected supply / notes |
|---|---|---|
| Insulin Lispro Junior KwikPen, Injection, 100 [iU]/1 mL (NDC 0002-7752-05) Eli Lilly and Co. |
A business decision was made to discontinue manufacture of the drug. Distribution projected to end June 2027. If patients or prescribers have any questions, the Lilly Answers Center (1-800-545-5979) is available Monday through Friday from 9am to 8pm for assistance. Being discontinued · September 1, 2026 |
|
| Humalog Mix 75/25, Injection, 100 [iU]/1 mL (NDC 0002-8233-05) Eli Lilly and Co. |
A business decision was made to discontinue manufacture of the drug. Distribution projected to end June 2027. If patients or prescribers have any questions, the Lilly Answers Center (1-800-545-5979) is available Monday through Friday from 9am to 8pm for assistance. Being discontinued · September 1, 2026 |
Recalls
-
Class II Completed
Sterile Diluent, HUMALOG U-100 (insulin lispro injection), HUMULIN R U-100 REGULAR (insulin human injection), Insulin Lispro Injection u-100, 10 mL, Use ONLY with Insulins listed on carton, Marketed by: Lilly USA, LLC, I…
Reason: CGMP Deviations
Lots, distribution and details
- Product
- Sterile Diluent, HUMALOG U-100 (insulin lispro injection), HUMULIN R U-100 REGULAR (insulin human injection), Insulin Lispro Injection u-100, 10 mL, Use ONLY with Insulins listed on carton, Marketed by: Lilly USA, LLC, Indianapolis, IN 46285. NDC: 0002-0800-01
- Lots / codes
- Batch number: D608951C, exp 4/10/2025
- Distribution
- Nationwide USA
- Quantity
- 700 vials
- Recall started
- March 12, 2024 (Voluntary: Firm initiated)
- Severity
- Could cause temporary or medically reversible health problems; serious harm is unlikely.
- FDA recall number
- D-0445-2024
-
Class II Ongoing
Admelog, insulin lispro injection, 100 units/mL (U-100), 3mL multi-dose vial, Rx Only, Sanofi-Aventis U.S. LLC, Bridgewater, NJ 08807 A Sanofi Company. NDC 0024-5926-05
Reason: Lack of Assurance of Sterility: Malformed crimped collar seal
Lots, distribution and details
- Lots / codes
- Lot # 3F497B, EXP 12-31-2025
- Distribution
- Nationwide in the USA
- Quantity
- 51,325 vials
- Recall started
- April 11, 2023 (Voluntary: Firm initiated)
- Severity
- Could cause temporary or medically reversible health problems; serious harm is unlikely.
- FDA recall number
- D-0575-2023
-
Class II Ongoing
Admelog Solostar (insulin lispro injection), 100 units/ mL (U-100) injection, packaged in 3mL prefilled pens, 1 pen per box, Rx only, Physician Sample – Not For Sale, Sanofi-Aventis U.S. LLC, Bridgewater, NJ 08807, NDC 0…
Reason: Temperature Abuse: Product samples of Admelog may not have been shipped at proper temperature.
Lots, distribution and details
- Product
- Admelog Solostar (insulin lispro injection), 100 units/ mL (U-100) injection, packaged in 3mL prefilled pens, 1 pen per box, Rx only, Physician Sample – Not For Sale, Sanofi-Aventis U.S. LLC, Bridgewater, NJ 08807, NDC 0024-5925-00
- Lots / codes
- Lot #: 7F021B, Exp 6/30/20
- Distribution
- Nationwide
- Quantity
- 3214 prefilled pens
- Recall started
- July 5, 2018 (Voluntary: Firm initiated)
- Severity
- Could cause temporary or medically reversible health problems; serious harm is unlikely.
- FDA recall number
- D-0925-2018
Have this medicine at home? Compare the lot number and expiry date on your package with the recall. Do not stop taking a prescribed medicine on your own — stopping suddenly can be riskier than the recalled lot. Your pharmacist can check it and usually swap it for an unaffected one.
Get alerts for Insulin Lispro
We will email you if the FDA reports a recall, if its shortage status changes, or when we publish news about it — at most one email a day. No account needed.
Source: FDA structured product labeling, retrieved through openFDA. Label text is shown as published by the FDA, without editing; long sections are shortened, marked […]. openFDA data are not validated for clinical use — always check the current label and ask a doctor or pharmacist about your own treatment. Set ID b34cd3ff-d0af-4852-b4ef-2a8b4a93aeae.