Advertisement



Drugs A–Z

Anti-Inhibitor Coagulant Complex

Anti-Inhibitor Coagulant Complex is a prescription medicine. The sections below reproduce one FDA label for it, named under "Label". Products in other forms, strengths or from other makers have their own labels, which can differ.

Type
Prescription only (Rx)
Brand names
Feiba
Label
Takeda Pharmaceuticals America, Inc., revised November 27, 2025 · full label on DailyMed
Generic
No · details

Boxed warning — the FDA's most serious warning for a medicine

WARNING: EMBOLIC and THROMBOTIC EVENTS Thromboembolic events have been reported during postmarketing surveillance following infusion of FEIBA, particularly following the administration of high doses and/or in patients with thrombotic risk factors. Monitor patients receiving FEIBA for signs and symptoms of thromboembolic events. WARNING: EMBOLIC and THROMBOTIC EVENTS See full prescribing information for complete boxed warning. Thromboembolic events have been reported during postmarketing surveillance, particularly following the administration of high doses and/or in patients with thrombotic risk factors. Monitor patients receiving FEIBA for signs and symptoms of thromboembolic events ( 5.1 , 6.2 ).

What it is used for

FEIBA is an Anti-Inhibitor Coagulant Complex indicated for use in hemophilia A and B patients with inhibitors for: Control and prevention of bleeding episodes Perioperative management Routine prophylaxis to prevent or reduce the frequency of bleeding episodes. FEIBA is not indicated for the treatment of bleeding episodes resulting from coagulation factor deficiencies in the absence of inhibitors to coagulation factor VIII or coagulation factor IX. FEIBA is an Anti-Inhibitor Coagulant Complex indicated for use in hemophilia A and B patients with inhibitors for: Control and prevention of bleeding episodes. Perioperative management. Routine prophylaxis to prevent or reduce the frequency of bleeding episodes. FEIBA is not indicated for the treatment of bleeding episodes resulting from coagulation factor deficiencies in the absence of inhibitors to factor VIII or factor IX. ( 1 )

Forms and strengths

FEIBA is available as a lyophilized powder in single-dose glass vials containing nominally 500, 1000, or 2500 units per vial. FEIBA is available as a lyophilized powder in single-dose vials containing nominally 500, 1000, or 2500 units per vial. ( 3 )

Who should not take it (contraindications)

Known anaphylactic or severe hypersensitivity reactions to FEIBA or any of its components, including factors of the kinin generating system. Disseminated intravascular coagulation (DIC). Acute thrombosis or embolism (including myocardial infarction). History of anaphylactic or severe hypersensitivity reactions to FEIBA or any of its components, including factors of the kinin generating system. ( 4 ) Disseminated intravascular coagulation (DIC). ( 4 ) Acute thrombosis or embolism (including myocardial infarction). ( 4 )

Warnings and precautions

FEIBA can cause thromboembolic events following doses above 200 units per kg per day and in patients with thrombotic risk factors. Monitor patients receiving FEIBA for signs and symptoms of thromboembolic events. ( 5.1 ) Anaphylaxis and severe hypersensitivity reactions may occur. Should symptoms occur, discontinue treatment with FEIBA and administer appropriate treatment. ( 5.2 ) FEIBA is made from human plasma and may contain infectious agents, e.g., viruses, the variant Creutzfeldt-Jacob disease (vCJD) and theoretically, Creutzfeldt-Jacob disease (CJD) agent. ( 5.3 )

5.1 Embolic and Thrombotic Events Thromboembolic events (including venous thrombosis, pulmonary embolism, myocardial infarction, and stroke) can occur with FEIBA, particularly following the administration of high doses (above 200 units per kg per day) and/or in patients with thrombotic risk factors [see Adverse Reactions (6) ] . Patients with DIC, advanced atherosclerotic disease, crush injury, septicemia, or concomitant treatment with recombinant factor VIIa have an increased risk of developing thrombotic events due to circulating tissue factor or predisposing coagulopathy. Potential benefit of treatment with FEIBA should be weighed against the potential risk of these thromboembolic events. Monitor patients receiving more than 100 units per kg of body weight of FEIBA for the development of DIC, acute coronary ischemia and signs and symptoms of other thromboembolic events. If clinical signs or symptoms occur, such as chest pain or pressure, shortness of breath, altered consciousness, vision, or speech, limb or abdomen swelling and/or pain, discontinue the infusion and initiate appropriate diagnostic and therapeutic measures. The safety and efficacy of FEIBA for breakthrough bleeding in patients receiving emicizumab has not been established. Cases of thrombotic microangiopathy (TMA) were reported in a clinical trial where subjects received FEIBA as part of a treatment regimen for breakthrough bleeding following treatment with emicizumab. 6 Consider the benefits and risks with FEIBA if considered required for patients receiving emicizumab prophylaxis. If treatment with FEIBA is required for patients receiving emicizumab, the hemophilia treating physician should closely monitor for signs and symptoms of TMA. In FEIBA clinical studies thrombotic microangiopathy (TMA) has not been reported.

5.2 Hypersensitivity Reactions Hypersensitivity and allergic reactions, including severe anaphylactoid reactions, can occur following the infusion of FEIBA. The symptoms include urticaria, angioedema, gastrointestinal manifestations, bronchospasm, and hypotension. These reactions can be severe and systemic (e.g., anaphylaxis with urticaria and angioedema, bronchospasm, and circulatory shock). Other infusion reactions, such as chills, pyrexia, and hypertension have also been reported. If signs and symptoms of severe allergic reactions occur, immediately discontinue administration of FEIBA and provide appropriate supportive care.

5.3 Transmission of Infectious Agents Because FEIBA is made from human plasma it may carry a risk of transmitting infectious agents, e.g., viruses, and the variant Creutzfeldt-Jakob disease (vCJD) agent, and theoretically, the Creutzfeldt-Jakob disease (CJD) agent. The risk has been minimized by screening plasma donors for prior exposure to certain viruses, by testing for the presence of certain current virus infections and by inactivating and removing certain viruses during the manufacturing process [see Description (11) ] . Despite these measures, the product may still potentially transmit human pathogenic agents. There is also the possibility that unknown infectious agents may still be present. All infections thought by a physician to have been possibly transmitted by this product should be reported by the physician or other healthcare providers to Takeda Pharmaceuticals U.S.A., Inc. at 1-877-TAKEDA-7 (1-877-825-3327) (in the U.S.) and /or to FDA Med Watch (1-800-FDA-1088 or www.fda.gov/medwatch ).

5.4 Presence of Isohemagglutinins and Interference with Laboratory Tests FEIBA contains blood group isohemagglutinins (anti-A and anti-B). Passive transmission of antibodies to erythrocyte antigens, e.g., A, B, D, may interfere with some serological tests for red cell antibodies, such as antiglobulin test (Coombs test).

Side effects (adverse reactions)

The most frequently reported adverse reactions observed in >5% of subjects in the prophylaxis trial were anemia, diarrhea, hemarthrosis, hepatitis B surface antibody positive, nausea, and vomiting. The serious adverse reactions seen with FEIBA are hypersensitivity reactions and thromboembolic events, including stroke, pulmonary embolism and deep vein thrombosis. The most common adverse reactions observed in >5% of subjects were anemia, diarrhea, hemarthrosis, hepatitis B surface antibody positive, nausea, and vomiting. ( 6.1 ) The serious adverse drug reactions are hypersensitivity and thromboembolic events, including stroke, pulmonary embolism, and deep vein thrombosis. ( 5.1 , 5.2 , 6 ) To report SUSPECTED ADVERSE REACTIONS, contact Takeda Pharmaceuticals U.S.A., Inc. at 1-877-TAKEDA-7 (1-877-825-3327) or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch .

6.1 Clinical Trials Experience Because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in clinical practice. The safety assessment of FEIBA is based on the review of the data from two prospective clinical trials in which FEIBA was used for the treatment of acute bleeding episodes and a prospective trial that compared the use of FEIBA prophylactically versus on-demand treatment. The adverse reactions reported from two prospective clinical trials in which FEIBA was used for the treatment of acute bleeding episodes were chills, chest pain, chest discomfort, dizziness, dysgeusia, dyspnea, hypoesthesia, increase of inhibitor titer (anamnestic response), nausea, pyrexia, and somnolence. Specifically, the first trial was a multicenter randomized, double-blind trial in 15 hemophilia A subjects with inhibitors to factors VIII. The second trial was a multicenter FEIBA study conducted in 44 hemophilia A subjects with inhibitors, 3 hemophilia B subjects with inhibitors and 2 acquired factor VIII inhibitor subjects. Of the 489 infusions used to treat acute bleeds during the second trial, 18 (3.7%) caused minor transient reactions of chills, fever, nausea, dizziness and dysgeusia. Out of 49 subjects, 10 (20%) had a rise in their inhibitor titers after treatment with FEIBA. Five of these subjects (50%) had increases that were tenfold or more, and 3 (30%) of these subjects received factor VIII or IX concentrates within 2 weeks prior to treatment with FEIBA. These anamnestic rises were not associated with decreased efficacy of FEIBA. Table 2 lists the adverse reactions in >5% of subjects reported in the randomized, prospective prophylaxis trial comparing FEIBA prophylaxis with on-demand treatment in 36 hemophilia A and B subjects with inhibitors to factors VIII or IX 3 . The trial population included 33 (92%) subjects with hemophilia A and 3 (8.3%) subjects with hemophilia B. Four (11%) subjects were ≥7 to <12 years of age, 5 (14%) were ≥12 to <16 years of age, and 27 (75%) were ≥16 years of age. A total of 29 (80.6%) subjects were Caucasian, 3 (8.3%) Asian, 2 (5.6%) Black/African American, and 2 (5.6%) other. The subjects received a total of 4,513 infusions (3,131 for prophylaxis and 1,382 for on-demand). Table 2: Prophylaxis Study Adverse Reactions (ARs) in >5% of Subjects MedDRA System Organ Class Adverse Reaction Number of ARs Number of Subjects Percent of Subjects (N=36) Blood And Lymphatic System Disorders Anemia 2 2

5.6 Gastrointestinal Disorders Diarrhea 2 2

5.6 Nausea 2 2

5.6 Vomiting 2 2

5.6 Investigations Hepatitis B Surface Antibody Positive 4 4

11.1 Musculoskeletal And Connective Tissue Disorders Hemarthrosis 5 3

8.3 Table 3 lists the adverse reactions and infusion related adverse events reported in >5% of subjects in any of the three groups (50% Reduced Volume, Increased Rate 4 U/kg/min; 50% Reduced Volume, Increased Rate 10 U/kg/min; Overall 50% Reduced Volume) of the randomized, prospective crossover trial evaluating the tolerability and safety of infusing reduced volume of FEIBA at the standard infusion rate of 2 U/kg/min, and at increased rates of 4 and 10 U/kg/min in a total of 33 treated subjects with congenital Hemophilia A with inhibitors. Table 3: Adverse Reactions (ARs) and Infusion Related Adverse Events in >5% of Subjects, in Patients 18 Years and Older MedDRA System Organ Class Adverse Reaction 50% Reduced Volume; Increased Rate 4 U/kg/min (N=30) n (%); m 50% Reduced Volume; Increased Rate 10 U/kg/min (N=28) n (%); m Overall 50% Reduced Volume Includes the following infusion rates: 2 U/kg/min; 4 U/kg/min and 10 U/kg/min (N=30) n (%); m n=Number of subjects, m=number of events Adverse reactions (ARs) Nervous system disorders Headache 0 0 2 (6.7%); 2 Infusion related AEs Nervous system disorders Headache 0 0 2 (6.7%); 2

6.2 Postmarketing Experience The following adverse reactions have been identified during post-approval use of FEIBA. Because postmarketing reporting of adverse reactions is voluntary and from a population of uncertain size, it is not always possible to reliably estimate the frequency of these reactions or establish a causal relationship to product exposure. Blood and Lymphatic System Disorders: disseminated intravascular coagulation Cardiac Disorders: tachycardia, flushing Respiratory, Thoracic, and Mediastinal Disorders: bronchospasm, wheezing Gastrointestinal Disorders: abdominal discomfort Skin and Subcutaneous Tissue Disorders: pruritus General Disorders and Administration Site Conditions: malaise, feeling hot, injection site pain Investigations: Fibrin D-dimer increased

Drug interactions

Consider the possibility of thrombotic events when systemic antifibrinolytics such as tranexamic acid and aminocaproic acid are used. Use of antifibrinolytics within approximately 6 to 12 hours after the administration of FEIBA is not recommended. ( 7 )

7.1 Concomitant Medications Consider the possibility of thrombotic events when systemic antifibrinolytics such as tranexamic acid and aminocaproic acid are used during treatment with FEIBA. No adequate and well-controlled studies of the combined or sequential use of FEIBA and recombinant factor VIIa antifibrinolytics, or emicizumab have been conducted. Use of antifibrinolytics within approximately 6 to 12 hours after the administration of FEIBA is not recommended. Clinical experience from an emicizumab clinical trial suggests that a potential drug interaction may exist with emicizumab when FEIBA was used as part of a treatment regimen for breakthrough bleeding 6 [see Warnings and Precautions (5.1) ] .

Pregnancy, breastfeeding, children and older adults

8.1 Pregnancy Risk Summary There are no data with FEIBA use in pregnant women to inform a drug-associated risk. There are no adequate and well-controlled studies in pregnant women. Animal reproduction studies have not been conducted with FEIBA. It is also not known whether FEIBA can cause fetal harm when administered to a pregnant woman or can affect reproductive capacity. In the U.S. general population, the estimated background risk for major birth defects and miscarriage in clinically recognized pregnancies is 2-4% and 15-20%, respectively. There is no information available on the effect of FEIBA on labor and delivery.

8.2 Lactation Risk Summary There is no information regarding the presence of FEIBA in human milk, the effect on the breastfed child, or the effects on milk production. The developmental and health benefits of breastfeeding should be considered along with the mother's clinical need for FEIBA and any potential adverse effects on the breastfed child from FEIBA or from the underlying condition.

8.4 Pediatric Use Safety and efficacy of FEIBA have been evaluated in nine pediatric subjects treated in the routine prophylaxis trial including 4 subjects ≥7 to <12 years of age and 5 subjects ≥12 to <16 years of age. The dosing for all pediatric subjects was based on body weight. A total of 576 infusions were given for the treatment of 223 bleeding episodes (504 infusions for joint bleeding episodes, 72 infusions for muscle and soft tissue bleeding episodes). In 223 (100%) of the episodes, hemostasis was achieved with one or more infusions. Hemostatic efficacy was rated as excellent or good in a majority (96.9%) of the bleeding episodes in both regimens at 24 hours post infusion. The median annualized bleeding episode rate (ABR) for children ≥7 to <12 years of age was 7.7 bleeds per patient per year, as compared to 39 for subjects treated with on-demand therapy [see Clinical Studies (14) ] . The safety and efficacy of FEIBA has not been evaluated in neonates.

8.5 Geriatric Use The safety and efficacy of FEIBA has not been evaluated in subjects ≥65 years of age.

How it works

The mechanism of action of FEIBA is still the subject of scientific discussion. FEIBA contains multiple components, mainly non-activated factors II, IX, X and mainly activated factor VII. These factors can interact with plasma coagulation factors and platelets to increase the impaired thrombin generation of hemophilia patients with inhibitors, leading to hemostasis.

Is there a generic Anti-Inhibitor Coagulant Complex?

No. The FDA has not approved a generic version yet.

Source: Drugs@FDA (via openFDA), checked October 29, 2026. Marketing status is what companies report to the FDA; whether a pharmacy stocks a product, and what your insurance covers, can differ.

Dosage:
we do not reproduce dosing instructions. The right dose depends on the person and the condition and is set by the prescriber or pharmacist. Dosage section of the full label.

Anti-inhibitor coagulant complex in the news

We have not covered this medicine yet. Latest news

Recalls

No recalls matched to this medicine in FDA enforcement reports from the last 3 years (or older ones still open). Search all recalls

Get alerts for Anti-Inhibitor Coagulant Complex

We will email you if the FDA reports a recall, if its shortage status changes, or when we publish news about it — at most one email a day. No account needed.









Source: FDA structured product labeling, retrieved through openFDA. Label text is shown as published by the FDA, without editing; long sections are shortened, marked […]. openFDA data are not validated for clinical use — always check the current label and ask a doctor or pharmacist about your own treatment. Set ID 752604e5-4ea2-44f4-83ed-1569373f6412.


Advertisement



Important: this content is for informational purposes only and is not medical advice, a prescribing instruction, or a recommendation to act. Consult a licensed healthcare professional before taking any medication.

Advertisement