Advertisement



Drugs A–Z

Technetium Tc99m Pyrophosphate

Technetium Tc99m Pyrophosphate is a prescription medicine (Radioactive Diagnostic Agent). The sections below reproduce one FDA label for it, named under "Label". Products in other forms, strengths or from other makers have their own labels, which can differ.

On the FDA shortage list — 2 products are unavailable or in limited supply. Which forms

Type
Prescription only (Rx)
Drug class
Radioactive Diagnostic Agent
Taken
Intravenous
Label
Sun Pharmaceutical Industries, Inc., revised March 11, 2025 · full label on DailyMed
Generic
No · details

What it is used for

Technetium Tc 99m Pyrophosphate Injection is a bone imaging agent used to demonstrate areas of altered osteogenesis, and a cardiac imaging agent used as an adjunct in the diagnosis of acute myocardial infarction. Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection is a blood pool imaging agent which may be used for gated blood pool imaging and for the detection of sites of gastrointestinal bleeding. When reconstituted with sterile non-pyrogenic isotonic saline and administered intravenously 30 minutes prior to the intravenous administration of Sodium Pertechnetate Tc 99m Injection, approximately 76% of the injected radioactivity remains in the blood pool.

Who should not take it (contraindications)

None known.

Warnings

As an adjunct in the diagnosis of confirmed myocardial infarction (ECG and serum enzymes positive), the incidence of false negative images has been found to be 6 percent. False negative images can also occur if made prior to 24 hours in the evolutionary phase of the infarct or after 6 days in the resolution phase. In a limited study involving 22 patients in whom the ECG was positive and serum enzymes questionable or negative, but in whom the final diagnosis of acute myocardial infarction was made, the incidence of false negative images was 23 percent. The incidence of false positive images has been found to be 7 to 9 percent. False positive images have also been reported following coronary by-pass graft surgery, in unstable angina pectoris, old myocardial infarcts and in cardiac contusions. Preliminary reports indicate impairment of brain scans using Sodium Pertechnetate Tc99m Injection which have been preceded by a bone scan using an agent containing stannous ions. The impairment may result in false positive or false negative brain scans. It is recommended, where feasible, that brain scans precede bone imaging procedures. Alternately, a brain imaging agent such as Technetium Tc 99m Pentetate Injection may be employed. The biodistribution of technetium Tc 99m pyrophosphate may be altered in the presence of high levels of certain cations (iron, calcium, and aluminum). This may result in reduced uptake of radionuclide in the skeleton and increased extraosseal uptake, which may potentially degrade imaging quality. High levels of these cations may be caused by concomitant medications or medical conditions (e.g., iron overload, hypercalcemia, etc.). Most cases were observed after iron infusion. (See PRECAUTIONS, Drug Interactions .)

Precautions

General The lyophilized contents of the Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection reaction vial are to be administered to the patient only as an intravenous solution (see Procedures for Reconstitution). Any Sodium Pertechnetate Tc 99m solution which contains an oxidizing agent is not suitable for use with Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection. When reconstituted with Sodium Pertechnetate Tc 99m, Technetium Tc 99m Pyrophosphate Injection must be used within 6 hours. Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection may also be reconstituted with sterile, non-pyrogenic isotonic saline containing no preservatives and injected intravenously prior to the administration of Sodium Pertechnetate Tc 99m Injection. Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection contains no preservatives. Vials are sealed under nitrogen: air or oxygen is harmful to the contents of the vials and the vials should not be vented. The components of the Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection are supplied sterile and non-pyrogenic. Aseptic procedures normally employed in making additions and withdrawals for sterile, non-pyrogenic containers should be used during addition of the Sodium Pertechnetate Tc 99m Injection and the withdrawal of doses for patient administration. Shielding should be utilized when preparing Technetium Tc 99m Pyrophosphate Injection. Technetium Tc 99m Pyrophosphate Injection as well as other radioactive drugs must be handled with care, and appropriate safety measures should be used to minimize radiation exposure to the patients and clinical personnel consistent with proper patient management. The solution should not be used if cloudy, discolored, or found to contain particulate matter. Radiopharmaceuticals should be used only by physicians who are qualified by training and experience in the safe use and handling of radionuclides, and whose experience and training have been approved by the appropriate government agency authorized to license the use of radionuclides. No special handling is required for the non-radioactive drug product. Bone Imaging Both prior to and following Technetium Tc 99m Pyrophosphate Injection administration, if not contraindicated for the patient’s cardiac condition, patients should be encouraged to drink fluids. Patients should void as often as possible after the Technetium Tc 99m Pyrophosphate Injection to minimize background interference and unnecessary radiation exposure from accumulation in the bladder. Cardiac Imaging Patient’s cardiac condition should be stable before beginning the cardiac imaging procedure. Interference from chest wall lesions such as breast tumors and healing rib fractures can be minimized by employing the three recommended projections. (See DOSAGE AND ADMINISTRATION ). False-positive and false-negative myocardial scans may occur; therefore, the diagnosis of acute myocardial infarction depends on the overall assessment of laboratory and clinical findings. Blood Pool Imaging The non-radioactive reconstituted agent should be injected by direct venipuncture. Heparinized catheter systems should be avoided, as interference with red blood cell tagging will result. Cardiac pool imaging should be initiated 15 to 30 minutes after the administration of Sodium Pertechnetate Tc 99m Injection. The imaging of gastrointestinal bleeding is dependent on such factors as the region of imaging, rate and volume of the bleed, efficacy of the labeling of the red blood cells and timeliness of imaging. Due to these factors, images should be taken sequentially over a period of time until a positive image is obtained or clinical conditions warrant the discontinuance of the procedure. The period of time for collecting the images may range up to 36 hours. Technetium Tc 99m Pyrophosphate Injection and the non-radioactive reconstituted Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection should be formulated within six (6) hours prior to clinical use. Drug Interactions The biodistribution of technetium Tc 99m pyrophosphate may be altered in the presence of high levels of certain cations (iron, calcium, and aluminum). This may result in reduced uptake of radionuclide in the skeleton and increased extraosseal uptake, which may potentially degrade imaging quality. In patients with high levels of these cations caused by concomitant medications, particularly patients receiving iron infusions, consider performing an imaging study with technetium Tc 99m pyrophosphate injection once the cation levels have normalized (e.g., after 3 to 5 half-lives of the cation). (See WARNINGS .) Carcinogenesis, Mutagenesis, Impairment of Fertility No long-term animal studies have been performed to evaluate carcinogenic potential or whether Technetium Tc 99m Pyrophosphate Injection affects fertility in males or females. Mutagenesis studies have not been conducted. Pregnancy Animal reproduction and teratogenicity studies have not been conducted with Technetium Tc 99m Pyrophosphate Injection. It is also not known whether Technetium Tc 99 Pyrophosphate Injection can cause fetal harm when administered to a pregnant woman or can affect reproductive capacity. Technetium Tc 99m Pyrophosphate Injection should be given to a pregnant woman only if clearly needed. Ideally, examinations using radiopharmaceuticals, especially those elective in nature, to a woman of childbearing capability should be performed during the first few (approximately 10) days following the onset of menses. Nursing mothers Technetium Tc 99m Pyrophosphate Injection is excreted in human milk during lactation, therefore, formula feeding should be substituted for breast feeding. Pediatric use Safety and effectiveness in pediatric patients have not been established. Geriatric use Clinical studies of the Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection did not include sufficient numbers of subjects aged 65 and over to determine whether they respond differently from younger subjects. Other reported clinical experience has not identified differences in responses between the elderly and younger patients. In general, dose selection for an elderly patient should be cautious, usually starting at the low end of the dosing range, reflecting the greater frequency of decreased hepatic, renal, or cardiac function, and of concomitant disease or other drug therapy. This drug is known to be substantially excreted by the kidney, and the risk of toxic reactions to this drug may be greater in patients with impaired renal function. Because elderly patients are more likely to have decreased renal function, care should be taken in dose selection, and it may be useful to monitor renal function.

Side effects (adverse reactions)

Some hypersensitivity reactions have been associated with pyrophosphate use.

Breastfeeding

Technetium Tc 99m Pyrophosphate Injection is excreted in human milk during lactation, therefore, formula feeding should be substituted for breast feeding.

Use in children

Safety and effectiveness in pediatric patients have not been established.

Use in older adults

Clinical studies of the Kit for the Preparation of Technetium Tc 99m Pyrophosphate Injection did not include sufficient numbers of subjects aged 65 and over to determine whether they respond differently from younger subjects. Other reported clinical experience has not identified differences in responses between the elderly and younger patients. In general, dose selection for an elderly patient should be cautious, usually starting at the low end of the dosing range, reflecting the greater frequency of decreased hepatic, renal, or cardiac function, and of concomitant disease or other drug therapy. This drug is known to be substantially excreted by the kidney, and the risk of toxic reactions to this drug may be greater in patients with impaired renal function. Because elderly patients are more likely to have decreased renal function, care should be taken in dose selection, and it may be useful to monitor renal function.

Is there a generic Technetium Tc99m Pyrophosphate?

No. The FDA has not approved a generic version yet.

Source: Drugs@FDA (via openFDA), checked October 29, 2026. Marketing status is what companies report to the FDA; whether a pharmacy stocks a product, and what your insurance covers, can differ.

Dosage:
we do not reproduce dosing instructions. The right dose depends on the person and the condition and is set by the prescriber or pharmacist. Dosage section of the full label.

Technetium tc99m pyrophosphate in the news

We have not covered this medicine yet. Latest news

Shortage status

Product Availability Expected supply / notes
CIS-PYRO, Injection, 12 mg/10 mL (NDC 45567-0060-2)
Sun Pharmaceutical Industries, Inc.
Unavailable Estimated Recovery: TBD
In shortage · October 19, 2026
CIS-PYRO, Injection, 12 mg/10 mL (NDC 45567-0060-1)
Sun Pharmaceutical Industries, Inc.
Unavailable Estimated Recovery: TBD
In shortage · October 19, 2026

All current drug shortages

Recalls

No recalls matched to this medicine in FDA enforcement reports from the last 3 years (or older ones still open). Search all recalls

Get alerts for Technetium Tc99m Pyrophosphate

We will email you if the FDA reports a recall, if its shortage status changes, or when we publish news about it — at most one email a day. No account needed.









Source: FDA structured product labeling, retrieved through openFDA. Label text is shown as published by the FDA, without editing; long sections are shortened, marked […]. openFDA data are not validated for clinical use — always check the current label and ask a doctor or pharmacist about your own treatment. Set ID 1f0cbd23-2fb3-43b7-b8af-7de246151149.


Advertisement



Important: this content is for informational purposes only and is not medical advice, a prescribing instruction, or a recommendation to act. Consult a licensed healthcare professional before taking any medication.

Advertisement